reorder
ALWAYS Be Happy search home
c
Combo Blog
Categories
Play Games New
Electronics
Electronics Accessories
Power
Power Strips & Surge Suppressors
UPS & Power
PDUs
APC

APC By Schneider Electric NetShelter 42-Outlets PDU - Switched - IEC 60309 60A (3P+PE) - 21 X IEC 60320 C13/C15, 21 X IEC 60320 C13/C15/C19/C21 - 230

About The Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. Outlet and PDU level power metering for power visibility and notification of potential overload. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss

Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. No interruption in Network communication, sensors operation, and alarm traps. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Outlet and PDU level power metering for power visibility and notification of potential overload. APDU10452SW Switched outlets to turn outlets on or off remotely. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss.

UPS & Power > PDUs

APC By Schneider Electric NetShelter 42-Outlets PDU - Switched - IEC 60309 60A (3P+PE) - 21 X IEC 60320 C13/C15, 21 X IEC 60320 C13/C15/C19/C21 - 230

UPS & Power > PDUs

Specifications of APC By Schneider Electric NetShelter 42-Outlets PDU - Switched - IEC 60309 60A (3P+PE) - 21 X IEC 60320 C13/C15, 21 X IEC 60320 C13/C15/C19/C21 - 230

CategoryElectronics > Electronics Accessories > Power > Power Strips & Surge Suppressors
Instockinstock

Last Updated

APC By Schneider Electric NetShelter 42-Outlets PDU - Switched - IEC 60309 60A (3P+PE) - 21 X IEC 60320 C13/C15, 21 X IEC 60320 C13/C15/C19/C21 - 230
More Varieties

Rating :- 8.81 /10
Votes :- 12